Product Type | ArmourColor |
Product Ref | PLG N5524 (PERLATA PLG N5524) |
Product Description | Decorative, water-based wall coatings offering seamless, hard wearing design alternatives to vinyl and wallpaper. |
Manufacturer | Armourcoat Ltd Unit 2-3a Morewood Close Sevenoaks Kent TN13 2HU UK |
Manufacturer Telephone | (+44) (0)1732 460 668 |
Manufacturer Email | estimating@armourcoat.co.uk |
Product Location | * |
Drawings | * |
Preparation | Coating will follow contour of substrate. Surfaces must be:
|
Primer | Apply 1 or more coats of ArmourColor BaseColor Matt and allow to dry. |
Application | Apply 2 coats of pre-mixed ArmourColor Perlata and finish as required. Apply ArmourColor Clearseal Gloss a minimum of 4-8 hours later (recommended in heavy traffic and vulnerable locations to improve abrasion resistance). |
Thickness | 0.10 - 0.30mm Please contact Armourcoat for further details |
Day Joints | Unless an expansion joint is advised by the substrate installer or structural engineer, the maximum area before the need for a day joint is 60 m2 |
Temperature | Products to be applied in temperatures 10 degrees Celsius and rising, n/e 30 degrees Celsius unless through consultation with manufacturer. |
Guarantee | 10 year guarantee for internal use. The current warranty document can be found at www.armourcoat.com |
Genuine Armourcoat | The system is to be supplied and applied by Armourcoat Ltd. No substitutes within the system are supported or allowed. |
Primary Component | PG Perlata Gold |
ASTM D3960 VOC Test (g/l) | 209.0000 |
ASTM D6886-03 VOC Test (g/l) | 74.4000 |
BSISO 11890 2 VOC Test (g/l) | 63.0000 |
JIS A 1901 VOC Test (micrograms/m2/h) | 1.00 |
ASTM E84-03 Fire Test Result | A |
BS 476 Fire Test | 0 |
Recycled Content Pctg | 25.00 |
ASTM D3274 Mould & Mildew Resistance Test | 10/10/10 |
ASTM D2486-06 Wet Scrub Cycles | 1075 |
French VOC Label | A+ |
Armourcoat products contain hand applied, natural mineral contents subject to pattern and tonal variation over and above those shown on samples. Product formulations may have changed since tests were conducted.
Base product test data to ASTM and BS standards not including substrate properties.
Whilst every attempt has been made to ensure the accuracy and reliability of the information contained in this document, the information should not be relied upon as a substitute for formal advice. Armourcoat Ltd, its employees and agents will not be liable for any loss or damage, of any kind, arising out of or in connection with the use of this document. Please refer to the company disclaimer for further details.